Danfoss logo
145G0190_92

EvoFlat WSS, Type 3, 10 bar, 95 °C, DHW controller name: TPC-M, Thermostat

145G0192

EvoFlat WSS 3, w/bypass, w/1 CW meter, with EPP front

Product specifications

Characteristic
Value
Application typeInstantaneous DHW
China RoHS complianceOut of scope
Connection directionBottom
Cover materialWhite-lacquered In wall
Cover optionExtra
Depth with cover [mm]150 mm
Depth without cover [mm]105 mm
DescriptionEvoFlat WSS 3, w/bypass, w/1 CW meter, with EPP front
DG Indicator ProfileContains Gas
DH connection size3/4"
DH connection typeG int. Thread
DH pipe sizeØ18
DHW capacity [kW] [Max]60 kW
DHW capacity [kW] [Min]40 kW
DHW connection size3/4"
DHW connection typeG int. Thread
DHW Control typeFlow/thermostatic
DHW controller nameTPC-M
DHW pipe sizeØ18
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
Fitting pieceEnergy meter return and cold water meter
HE connection size3/4"
HE connection typeG int. Thread
Characteristic
Value
HE pipe sizeØ18
Heat exchanger test pressure [bar]38 bar
Heating circuit - controlThermostat
Heating system typeDHW only
Height with cover [mm]575 mm
Height without cover [mm]575 mm
HEX heating brazing materialCopper
In scope of WEEE and contain batteriesNo
Manufacturer's nameDanfoss
Material DescriptionEvoFlat Water Heater 3 TPC-M w/cover
Number of households [Max]2
Number of households [Min]1
Pressure nominal primary [bar]10 bar
Pressure nominal secondary [bar]10 bar
Product groupSmall Stations
Product lineSubsystems
Product TypeEvoFlat WSS
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Station size typeType 3
Supply temperature construction [˚C]95 °C
UK RoHS complianceOut of scope
Width with cover [mm]545 mm
Width without cover [mm]545 mm

General specifications

Characteristic
Value
Gross weight12.161 Kilogram
Net weight11.095 Kilogram
Volume79.909 Liter
Characteristic
Value
EAN5702424653934
Proposition 65Cancer and Reproductive Harm