Danfoss logo
Indirect heating and instantaneous DHW-product-category

Indirect heating and instantaneous DHW

Product types shown: 30

  • Tile image

    Akva Lux II VX (A237)

  • Tile image

    Akva Lux II VX (Electronic)

  • Tile image

    Akva Lux II VX (Thermostatic)

  • Tile image

    Akva Lux II VX H2WP, ECL, 2 HE circ

  • Tile image

    Akva Lux II VXe (A237)

  • Tile image

    Akva Lux II VXe HT

  • Tile image

    Akva Lux II VXi (A237)

  • Tile image

    Akva Lux II VXi (A337)

  • Tile image

    Akva Lux II VXi, w/o controller

  • DID pre-configured stations category image

    DID pre-configured stations

  • DSA2 HOME category image

    DSA2 HOME

  • DSA2 WALL category image

    DSA2 WALL

  • DSP2 FIX category image

    DSP2 FIX

  • EvoFlat VX-F FH category image

    EvoFlat VX-F FH

    The VX-F is a compact flat station distinguished by high performance and ease of operation. The EvoFlat VX-F station is particularly suitable for two-pipe systems with underfloor heating supplied by a central heat generator in multi-family buildings. The VX-F FH stations can be used either independently or in combination with a VX-F heating circuit manifold with 2 to 12 heating circuits.

    Primary side
    The station is supplied with heating water from a heat source. The apartment station is factory‑equipped with a domestic hot water thermostat, differential pressure controller, strainer, summer bypass (FJVR), M10 sensor holder, and a fitting for the installation of a heat meter.

    Secondary side
    The secondary side consists of a plate heat exchanger, safety valve, pressure gauge, expansion vessel, and circulation pump.
    To regulate the supply temperature to the secondary side, a temperature controller of type FTC is used. The EvoFlat VX-F FH is equipped with a safety temperature limiter (55 °C) and a RA‑C zone valve with a TWA thermal actuator, which prevents further heat supply in the event of overheating.

    Domestic Hot Water (DHW)
    Domestic water heating is carried out using a heat exchanger in a flow‑through principle. The domestic water temperature is regulated by the automatic controller type TPC‑M. This combination controller offers exceptional user convenience by functioning as both a hydraulic and a thermostatic valve.
    The flow‑controlled section allows primary and secondary side flow through the heat exchanger only during domestic hot water draw‑off. Immediately after the draw‑off ends, the flow is shut off. The thermostatic section, on the other hand, regulates the domestic hot water temperature. The TPC‑M controller ensures a constant domestic hot water temperature even in the presence of fluctuating supply temperatures and differential pressures.

  • EvoFlat VX-F R category image

    EvoFlat VX-F R

    The VX-F is a compact flat station distinguished by high performance and ease of operation. The EvoFlat VX-F station is particularly suitable for two-pipe systems with underfloor heating supplied by a central heat generator in multi-family buildings.
    The VX-F R stations are for connecting radiators.

    Primary side
    The station is supplied with heating water from a heat source. The apartment station is factory‑equipped with a domestic hot water thermostat, differential pressure controller, strainer, summer bypass (FJVR), M10 sensor holder, and a fitting for the installation of a heat meter.

    Secondary side
    The secondary side consists of a plate heat exchanger, safety valve, pressure gauge, expansion vessel, and circulation pump.
    To regulate the supply temperature a temperature controller of type FTC is used.

    Domestic Hot Water (DHW)
    Domestic water heating is carried out using a heat exchanger in a flow‑through principle. The domestic water temperature is regulated by the automatic controller type TPC‑M. This combination controller offers exceptional user convenience by functioning as both a hydraulic and a thermostatic valve.

    The flow‑controlled section allows primary and secondary side flow through the heat exchanger only during domestic hot water draw‑off. Immediately after the draw‑off ends, the flow is shut off. The thermostatic section, on the other hand, regulates the domestic hot water temperature. The TPC‑M controller ensures a constant domestic hot water temperature even in the presence of fluctuating supply temperatures and differential pressures.

  • Tile image

    Heating module

  • Tile image

    Safety thermostat

  • Tile image

    Sensor adapter

  • Tile image

    Termix Compact 28 MS VVX

  • Tile image

    Termix Compact 28 MST VVX

  • Termix Compact 28 VVX-FI category image

    Termix Compact 28 VVX-FI

  • Tile image

    Termix Compact 32 VVX

  • Termix KST category image

    Termix KST

  • Tile image

    Termix VVX-B

  • Tile image

    Termix VVX-B HWP

  • Tile image

    Termix VVX-I FI

  • Tile image

    Termix VVX-ID

  • Tile image

    Termix VVX-Q

  • Tile image

    VX 22 (A230)

  • Tile image

    VX 22 (A266)