Pressostati
An electronic pressure switch offers a multitude of advantages in comparison to a mechanical pressure switch.These advantages include greater accuracy, freedom from contact wear out, excellent long-term stability, simpler operation and a high number of switching cycles, and many more.
Product types shown: 7

BCP
The BCP type is a series of dedicated pressure switches for safety and pressure monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where the contact position depends on the pressure in the connection port and the range set value. For installations, in which operation is particularly critical for safety reason, the use of fail-safe control is recommended.

CS
I pressostati CS sono dotati di un interruttore tripolare integrato azionato dalla pressione. La posizione di contatto dell'interruttore dipende dalla pressione nel connettore, dall'impostazione del campo e dal differenziale regolabile. I pressostati sono muniti di un interruttore manuale che blocca il di contatto in posizione aperta indipendentemente dalla pressione nel sistema. I pressostati con valvola di sicurezza sono utilizzati nei sistemi ad aria compressa in cui è necessario scaricare la pressione sul pistone del compressore prima dell'avvio. Il CS è idoneo per l'avvio e l'arresto automatico di compressori d'aria e gruppi di pompaggio acqua.

KP / KPI
I pressostati e i termostati KP e KPI sono utilizzati nei sistemi di controllo, monitoraggio e allarme in un'ampia varietà di applicazioni industriali.
I pressostati KP sono utilizzati principalmente per fluidi gassosi, mentre i pressostati KPI sono più adatti per fluidi liquidi e gassosi. I prodotti sono disponibili con grado di protezione IP30 e IP55.
La gamma di pressostati KP comprende pressostati e limitatori appositamente progettati per caldaie a vapore e altre applicazioni di riscaldamento.
Per il controllo e la protezione della pompa dell'acqua (funzionamento a secco) il pressostato doppio KP44 è adatto e garantisce una maggiore durata della pompa dell'acqua
KPS
The KPS series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for a high level of enclosure, robust and compact construction, and resistance to shock and vibration.
For KPS pressure switches the position of the contacts depends on the pressure in the inlet connection and the set scale value.
For KPS thermostats the position of the contacts depends on the temperature of the sensor and the set scale value.
The series covers most outdoor as well as indoor application requirements and is suitable for use in monitoring alarm and control systems in factories, diesel plants, compressors, power stations and on board ships.
MBC 5000 / MBC 5100
Gli interruttori di pressione MBC sono utilizzati in applicazioni industriali e marine dove lo spazio e l'affidabilità sono le caratteristiche più importanti.
Gli MBC sono pressostati compatti, progettati secondo la nostra struttura a blocchi per resistere alle condizioni estreme tipiche delle sale macchine a bordo delle navi.
I dispositivi MBC offrono un'elevata resistenza alle vibrazioni e il modello MBC 5100 è dotato di tutte le certificazioni marine più comuni. Il differenziale fisso, ma basso, garantisce un monitoraggio accurato delle pressioni critiche.
Le valvole di prova MBV possono essere fornite come opzione standard per MBC.
RT
RT pressure switches incorporate a pressure controlled, single-pole change over switch where the contact position depends on the pressure in the connection port and the set value. The RT series consists of pressure switches, differential pressure switches and pressure switches for neutral zone regulation, all for general use within the industrial and marine segments. The series also covers safety pressure switches dedicated for steam boiler plants. For installations in which operation is particularly critical from safety and economic points of view, the use of fail-safe pressure switches is recommended. The use of gold-plated contacts is also recommended in such installations, provided operation involves only a few switching cycles or signal currents and voltages.