Thermo. operated water valve, AVTA 20, NPT, 3/4-14
003N7182
Body material: Brass, Opening configuration: Opens on rising sensor temp., Charge type: Universal
Product specifications
Characteristic | Value |
|---|---|
| Approval | EACLLC CDC TYSKPEDRoHSRoHS China |
| Body material | Brass |
| Cap. tube length fraction [in] | 78 3/4 in |
| Capillary tube gland Int/Ext | Internal |
| Capillary tube gland size [in] | 3/4-14 |
| Capillary tube gland standard | ANSI/ASME B1.20.1 |
| Capillary tube gland type | NPT |
| Capillary tube length [mm] | 2000 mm |
| Charge type | Universal |
| China RoHS compliance | Yes |
| Connection Internal/External | Internal |
| Connection size [in] | 3/4-14 |
| Connection standard | ANSI/ASME B1.20.1 |
| Connection type | NPT |
| Contains batteries | No |
| Cv value [gal/min] | 3.900 gal/min |
| DG Indicator Profile | Contains Liquids |
| Differential pressure [bar] [max] | 10.000 bar |
| Differential pressure [bar] [min] | 0.000 bar |
| Differential pressure [psi] [max] | 145.000 psi |
| Differential pressure [psi] [min] | 0.000 psi |
| EU RoHS compliance | Yes with exemptions |
| EU RoHS exemption clause | 6(b)6(c) |
| Flow direction indicator | Embossed 1-way arrow |
| Kv value [m³/h] | 3.400 m³/h |
| Material Description | AVTA 20 Water Reg. Valve 50-90°C M/10 |
| Max. pressure on sensor [bar] | 25 bar |
| Max. pressure on sensor [psig] | 362.6 psig |
| Max. sensor temperature [°C] | 125 °C |
| Max. sensor temperature [°F] | 257.0 °F |
Characteristic | Value |
|---|---|
| Max. test pressure [bar] Pe | 25.0 bar |
| Max. test pressure [psig] | 362.6 psig |
| Max. Working Pressure [bar] | 16.0 bar |
| Max. Working Pressure [psig] | 232 psig |
| Media | Neutral media |
| Medium temperature range [°C] [max] | 130 °C |
| Medium temperature range [°C] [min] | -25 °C |
| Medium temperature range [°F] [max] | 266 °F |
| Medium temperature range [°F] [min] | -13 °F |
| Opening configuration | Opens on rising sensor temp. |
| Orifice size [mm] | 20.00 mm |
| Orifice size fraction [in] | 4/5 in |
| Packing format | Multi pack |
| Product accessories | Generic accessoriesWater valves accessories |
| Product group | Water regulating valves |
| Product line | Air Conditioning and Commercial Refrigeration |
| Product name | Thermo. operated water valve |
| Product Type | AVTA 20 |
| Quantity per packing format | 10 pc |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
| SCIP dossier no. | a698bb81-6c39-4d14-a29f-0fc686728af9 |
| SCIP dossier product name | AVTA FJVA |
| Sensor size (Ø x L) [in] | 23/32 x 8 1/4 in |
| Sensor size (Ø x L) [mm] | 18 x 210 mm |
| Serviceable | Water valve spare parts |
| Temperature range [°C] [max] | 90 °C |
| Temperature range [°C] [min] | 50 °C |
| Temperature range [°F] [max] | 194 °F |
| Temperature range [°F] [min] | 122 °F |
General specifications
Characteristic | Value |
|---|---|
| Gross weight | 1.678 Kilogram |
| Net weight | 1.398 Kilogram |
| Volume | 4.082 Liter |
Characteristic | Value |
|---|---|
| EAN/UPC | 5702423203468 |
| Proposition 65 | Cancer and Reproductive Harm |