Danfoss logo
MBT 5560 Temperature sensor, Pg9, M18x1-5

Temperature transmitter, MBT 5560, 50 mm, M,14x1.5

084Z4125

Temperature range [°C]: -50 - 200, Electrical connection: Angular connector, Electrical connection size: Pg 9, Protection tube material: AISI 316 Ti

Product specifications

Characteristic
Value
Ambient temperature max. [°C]85 °C
Ambient temperature max. [°F]185 °F
CE evaluatedYes
China RoHS complianceYes exceed limitations
Connection materialAISI 316 Ti
Connection standardISO 228
Connection typeM
DG Indicator ProfileNot relevant for dangerous goods
EEE category5 small equipment (any external dimension < 50 cm)
Electrical conn. Male/FemaleMale and Female
Electrical connectionAngular connector
Electrical connection sizePg 9
Electrical connection standardEN 175301-803-A
Enclosure rating IPIP65
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(a)6(b)6(c)7(a)7(c)-I
In scope of WEEEYes
In scope of WEEE and contain batteriesNo
Insertion length [in]1.970 in
Insertion length [mm]50 mm
Insertion typeFixed
Material DescriptionSensor MBT 5560-0000-0050-1B-815
Output signal [mA] [max]20 mA
Output signal [mA] [min]4 mA
Packing formatMulti pack
Process connection Male/FemaleMale
Process connection materialStainless steel
Process connection size14x1.5
Process connection standardISO 965
Process connection typeM
Characteristic
Value
Product groupSensors
Product lineSensing Solutions
Product nameTemperature transmitter
Product TypeMBT 5560
Protection tube diameter [in]0.315 in
Protection tube diameter [mm]8.0 mm
Protection tube materialAISI 316 Ti
Quantity per packing format13 pc
REACH Candidate List substancesLead (CAS no. 7439-92-1)Dodecamethylcyclohexasiloxane (D6, CAS no. 540-97-6)
Sensor elem. resistance [Ohm]1000 Ohm
Sensor element tolerance< ± 1% FS
Sensor element typePt
Sensor InsertFixed
Supply voltage [V] DC [max]32 V
Supply voltage [V] DC [max]32.00 V
Supply voltage [V] DC [min]10 V
Supply voltage [V] DC [min]10.00 V
Temperature range [°C] [max]200 °C
Temperature range [°C] [min]-50 °C
Temperature range [°F] [max]392 °F
Temperature range [°F] [min]-58 °F
Transmitter setting range [°C] [max]150 °C
Transmitter setting range [°C] [min]-40 °C
Transmitter setting range [°F] [max]302 °F
Transmitter setting range [°F] [min]-40 °F
Transmitter typeIntegrated
Type designationMBT 5560-0000-0050-1B-815
UK RoHS complianceYes with exemptions
UK RoHS exemption clause1215181921

General specifications

Characteristic
Value
Gross weight0.145 Kilogram
Net weight0.112 Kilogram
Volume0.489 Liter
Characteristic
Value
EAN5702428400688
Proposition 65Cancer and Reproductive Harm