Danfoss logo
VX Solo II H2

VX Solo II H2, 2 HE circuits, Type 2, Heating controller name: ECL 210 / A260

004U8289

Product Type: VX Solo II H2, 2 HE circuits, Type 2, 16 bar, 110 °C, VMV 15 / AMV 150

Product specifications

Characteristic
Value
Additional information2x Safety functionCoverPipe insulation
Application typeIndirect Heating
Capacity [kW]30.0 kW
China RoHS complianceOut of scope
Connection directionTop and bottom
Contain batteriesNo
Cover materialWhite-lacquered steel sheet
Cover optionIncluded
DG Indicator ProfileNot relevant for dangerous goods
DH connection size3/4"
DH connection typeExternal thread
DH pipe sizeØ18
DHW pipe sizeØ18
Depth with cover [mm]380 mm
Depth without cover [mm]365 mm
DescriptionVX Solo II H2 Type 2, ECL210, with Safety thermostat FH, with insulation
Differential pressure controllerIntegrated in control valve
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
Floor heating circuit - pump brandGrundfos
Floor heating circuit - pump typeUPM3 Auto 15-70 130
HE connection size3/4"
HE connection typeInternal thread
HE pipe sizeØ18
HEX heating alloyAISI 316
HEX heating brazed/gasketed materialBrazed copper
Heat exchanger test pressure [bar]38 bar
Heating ActuatorAMV 13
Heating Control valveAHQM 15
Heating HEX typeXB06H-1 40
Characteristic
Value
Heating capacity [kW]30 kW
Heating control typeElectronic
Heating controller nameECL 210 / A260
Heating pump brandGrundfos
Heating pump typeUPM3 Auto 15-70 130
Height with cover [mm]860 mm
Height without cover [mm]860 mm
In scope of WEEENo
Insulation materialEPDM
Material DescriptionVX-SOLO II H2 ECL210/A260 TYPE 2 STW
Material Description (Short TeVX Solo II H2, TYPE 2, STW
Mixing circuit - controlVMV 15 / AMV 150
Number of households [Max]1
Number of households [Min]1
Package depth [mm]620 mm
Package height [mm]420 mm
Package width [mm]840 mm
Pressure nominal primary [bar]16 bar
Pressure nominal secondary [bar]6 bar
Product TypeVX Solo II H2, 2 HE circuits
Product groupSmall Stations
Product lineLight Duty Stations
REACH Candidate List substancesLead (CAS no. 7439-92-1)
RemarksIndir. HE, ECL210/260, 2 x safety function and pipe insul.
Station size typeType 2
Supply temperature construction [˚C]110 °C
Supply voltage [V] AC230 V
UL evaluatedOut of scope
Width with cover [mm]550 mm
Width without cover [mm]530 mm

General specifications

Characteristic
Value
Gross weight45 Kilogram
Net weight43 Kilogram
Volume219.555 Liter
Characteristic
Value
EAN/UPC5715162510476
Proposition 65Cancer and Reproductive Harm