EvoFlat four pipe, Bottom, Brazed copper, Type 3
145B0506
EvoFlat FSS 1, w/bypass, w/1 CW meter, w/o EPP front
This product has been discontinued.
The product is no longer available for purchase, but you can still find information about it, including service manuals, drawing etc.
If you're looking for a similar product, you can check out other options within the same product type by visiting the product type page.: EvoFlat four pipe
Product specifications
Characteristic | Value |
---|---|
Application type | Direct Heating & Instantaneous DHW |
Approval | CE |
CE evaluated | Yes |
Connection direction | Bottom |
Cover material | White-lacquered In wall |
Cover option | Extra |
DCW static pressure [bar] [Min] | 2 bar |
DG Indicator Profile | Contains Gas |
DH connection size | 3/4" |
DH connection type | G int. Thread |
DH pipe size | Ø18 |
DHW Control type | Flow/thermostatic |
DHW HEX type | XB06H-1 26 |
DHW capacity [kW] | 37 kW |
DHW circulation | Without |
DHW connection size | 3/4" |
DHW connection type | G int. Thread |
DHW controller name | TPC-M |
DHW pipe size | Ø18 |
Depth with cover [mm] | 153 mm |
Depth without cover [mm] | 110 mm |
Description | EvoFlat FSS 1, w/bypass, w/1 CW meter, w/o EPP front |
Differential pressure controller | Integrated |
EU RoHS compliance | Yes with exemptions |
EU RoHS exemption clause | 6(c) |
HE connection size | 3/4" |
HE connection type | G int. Thread |
HE pipe size | Ø18 |
HEX DHW brazed/gasketed material | Brazed copper |
HEX heating brazed/gasketed material | Copper |
Characteristic | Value |
---|---|
Heat exchanger test pressure [bar] | 38 bar |
Heating capacity [kW] [Max] | 15 kW |
Heating capacity [kW] [Min] | 10 kW |
Heating control type | Differential pressure |
Heating controller name | TPC-M |
Heating system type | Radiator and Floor heating |
Height with cover [mm] | 590 mm |
Height without cover [mm] | 590 mm |
In scope of WEEE | No |
Insulation material | Without |
Manufacturer's name | Danfoss |
Material Description | EvoFlat Four Pipe A3 TPC-M 22L/min |
Mixing circuit - control | Thermostat |
Number of households [Max] | 2 |
Number of households [Min] | 1 |
Package depth [mm] | 600 mm |
Package height [mm] | 160 mm |
Package width [mm] | 800 mm |
Pressure nominal primary [bar] | 10 bar |
Pressure nominal secondary [bar] | 10 bar |
Product Type | EvoFlat four pipe |
Product group | Small Stations |
Product line | Subsystems |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Remarks | Insulated Flatstations |
Station size type | Type 3 |
Supply temperature construction [˚C] | 95 °C |
UL evaluated | Out of scope |
Width with cover [mm] | 545 mm |
Width without cover [mm] | 545 mm |
General specifications
Characteristic | Value |
---|---|
Gross weight | 15.17 Kilogram |
Net weight | 13.97 Kilogram |
Characteristic | Value |
---|---|
Volume | 82.11 Liter |
EAN/UPC | 5702428524544 |