Isı Eşanjörlü Anlık Su Isıtıcıları
Instantaneous water heaters provide hot water instantaneously and only as it is needed. Danfoss offers a comprehensive range of products with different control solutions based on principles of flow, thermostatic, flow and thermostatic or electronic controlling. When you turn on a hot water tap in your home, cold water travels through a pipe into a heat exchanger in the unit. The cold water is heated in the heat exchanger via district heating water or another waterborne heat source. As a result, the water heaters deliver a constant supply of instant hot water.
Product types shown: 21

Akva Therm 22 (Electronic)
Water heater for domestic hot water production based on the instantaneous heating principle, designed for use in district heating systems.Supplied as a wall-mounted solution with self-acting or automatic control of the domestic hot water temperature.
Application
Akva Therm 22 can be used directly in district heating systems. The water heater has sufficient capacity to supply a property with 5 to 25 apartments or a smaller commercial building/sports facility with shower facilities for up to 60 people.
Description
The water heater includes an insulated, brazed plate heat exchanger for domestic hot water production, a thermostatic controller or Danfoss automatic controller for domestic hot water regulation, a thermometer, an energy-efficient pump, a strainer, safety valve, and check valve on the cold water inlet. Alternatively, it can be supplied with a Danfoss ECL 310 automatic controller. Akva Therm 22 can also be supplied with a plate heat exchanger solution featuring Danfoss ECL 310 automatic control.
Water Heater
The unit is based on a high-efficiency plate heat exchanger with optimal cooling of the district heating water. The domestic hot water temperature is controlled either thermostatically or by a Danfoss ECL 110 controller.
Domestic Hot Water Circulation
The water heater is supplied as standard with connections for domestic hot water circulation and is equipped with an energy-efficient pump, check valve, and balancing valve. The pump, balancing valve, and check valve are pre-mounted on the circulation line with flow direction toward the water heater. The water heater must always be connected to a domestic hot water circulation system. If circulation is not available in the building installation, an internal circulation loop must be established within the technical room to ensure continuous flow on the secondary side of the water heater. Domestic hot water circulation provides hot water at the tapping point without waiting time and without water wastage. This ensures optimum comfort and good heating economy.
Note: It is recommended to install a differential pressure controller upstream of the water heater if the district heating supply pressure exceeds 8 m water column, to prevent noise.
Service- and Installation-Friendly
A practical pipe arrangement and compact assembly of the components make the unit easy to service and install. Installation is quick and simple. The water heater is wall-mounted, and all connection points are positioned at a distance from the wall, making it possible to achieve neat pipework.
Akva Therm 22 (Thermostatic)
Water heater for domestic hot water production based on the instantaneous heating principle, designed for use in district heating systems.Supplied as a wall-mounted solution with self-acting or automatic control of the domestic hot water temperature.
Application
Akva Therm 22 can be used directly in district heating systems. The water heater has sufficient capacity to supply a property with 5 to 25 apartments or a smaller commercial building/sports facility with shower facilities for up to 60 people.
Description
The water heater includes an insulated, brazed plate heat exchanger for domestic hot water production, a thermostatic controller or Danfoss automatic controller for domestic hot water regulation, a thermometer, an energy-efficient pump, a strainer, safety valve, and check valve on the cold water inlet. Alternatively, it can be supplied with a Danfoss ECL 310 automatic controller. Akva Therm 22 can also be supplied with a plate heat exchanger solution featuring Danfoss ECL 310 automatic control.
Water Heater
The unit is based on a high-efficiency plate heat exchanger with optimal cooling of the district heating water. The domestic hot water temperature is controlled either thermostatically or by a Danfoss ECL 110 controller.
Domestic Hot Water Circulation
The water heater is supplied as standard with connections for domestic hot water circulation and is equipped with an energy-efficient pump, check valve, and balancing valve. The pump, balancing valve, and check valve are pre-mounted on the circulation line with flow direction toward the water heater. The water heater must always be connected to a domestic hot water circulation system. If circulation is not available in the building installation, an internal circulation loop must be established within the technical room to ensure continuous flow on the secondary side of the water heater. Domestic hot water circulation provides hot water at the tapping point without waiting time and without water wastage. This ensures optimum comfort and good heating economy.
Note: It is recommended to install a differential pressure controller upstream of the water heater if the district heating supply pressure exceeds 8 m water column, to prevent noise.
Service- and Installation-Friendly
A practical pipe arrangement and compact assembly of the components make the unit easy to service and install. Installation is quick and simple. The water heater is wall-mounted, and all connection points are positioned at a distance from the wall, making it possible to achieve neat pipework.
Akva Therm 28 (Electronic)
Domestic hot water unit for instantaneous domestic hot water production, designed for use in district heating systems.Supplied as a wall-mounted solution and fully insulated in accordance with DS 452, including pipe insulation and an insulated cover.Available with either self-acting or automatic control of the domestic hot water temperature.
Application
Akva Therm 28 can be used directly in district heating systems. The domestic hot water unit has sufficient capacity to supply a property with 29 to 58 apartments or a smaller commercial building/sports facility with shower facilities for up to 120 people.
Description
The domestic hot water unit includes an insulated, brazed plate heat exchanger for domestic hot water production, a thermostat/controller or Danfoss ECL 110 automatic controller for domestic hot water regulation, shut-off valves, a thermometer, a balancing valve, an energy-efficient pump, a strainer, a balancing valve on the circulation line, and a check valve on the cold water inlet. Alternatively, it can be supplied with a Danfoss ECL 310 automatic controller. Akva Therm 28 is also available as a plate heat exchanger solution with Danfoss ECL 310 automatic control.
Domestic Hot Water Heat Exchanger
The unit is based on a high-efficiency plate heat exchanger with optimal cooling of the district heating water. Akva Therm 28 is available with a copper-brazed heat exchanger. The domestic hot water temperature is controlled either by a thermostat or by a Danfoss ECL 110 controller, alternatively ECL 310.
Domestic Hot Water Circulation
The domestic hot water unit is supplied as standard with connections for domestic hot water circulation and is equipped with an energy-efficient pump, check valve, and balancing valve. The pump, balancing valve, and check valve are pre-mounted on the circulation line with the flow direction towards the water heater. The domestic hot water unit must always be connected to a domestic hot water circulation system. If no circulation system is available in the building installation, an internal circulation loop must be established in the plant room to ensure continuous flow on the secondary side of the water heater. Domestic hot water systems with circulation provide hot water at the tapping point without waiting time and without water wastage. This ensures optimum comfort and good district heating economy.
Service- and Installation-Friendly
A practical pipe arrangement and compact assembly of the components make the domestic hot water unit easy to service and install. Installation is quick and simple. The water heater is wall-mounted, and all connection points are positioned at a distance from the wall, making it possible to achieve neat pipework.
Akva Therm 28 (Thermostatic)
Domestic hot water unit for instantaneous domestic hot water production, designed for use in district heating systems.Supplied as a wall-mounted solution and fully insulated in accordance with DS 452, including pipe insulation and an insulated cover.Available with either self-acting or automatic control of the domestic hot water temperature.
Application
Akva Therm 28 can be used directly in district heating systems. The domestic hot water unit has sufficient capacity to supply a property with 29 to 58 apartments or a smaller commercial building/sports facility with shower facilities for up to 120 people.
Description
The domestic hot water unit includes an insulated, brazed plate heat exchanger for domestic hot water production, a thermostat/controller or Danfoss ECL 110 automatic controller for domestic hot water regulation, shut-off valves, a thermometer, a balancing valve, an energy-efficient pump, a strainer, a balancing valve on the circulation line, and a check valve on the cold water inlet. Alternatively, it can be supplied with a Danfoss ECL 310 automatic controller. Akva Therm 28 is also available as a plate heat exchanger solution with Danfoss ECL 310 automatic control.
Domestic Hot Water Heat Exchanger
The unit is based on a high-efficiency plate heat exchanger with optimal cooling of the district heating water. Akva Therm 28 is available with a copper-brazed heat exchanger. The domestic hot water temperature is controlled either by a thermostat or by a Danfoss ECL 110 controller, alternatively ECL 310.
Domestic Hot Water Circulation
The domestic hot water unit is supplied as standard with connections for domestic hot water circulation and is equipped with an energy-efficient pump, check valve, and balancing valve. The pump, balancing valve, and check valve are pre-mounted on the circulation line with the flow direction towards the water heater. The domestic hot water unit must always be connected to a domestic hot water circulation system. If no circulation system is available in the building installation, an internal circulation loop must be established in the plant room to ensure continuous flow on the secondary side of the water heater. Domestic hot water systems with circulation provide hot water at the tapping point without waiting time and without water wastage. This ensures optimum comfort and good district heating economy.
Service- and Installation-Friendly
A practical pipe arrangement and compact assembly of the components make the domestic hot water unit easy to service and install. Installation is quick and simple. The water heater is wall-mounted, and all connection points are positioned at a distance from the wall, making it possible to achieve neat pipework.
Akva Therm 35 (Electronic)
Domestic hot water unit for instantaneous domestic hot water production, designed for use in district heating systems. Supplied as a wall-mounted solution and fully insulated in accordance with DS 452, including pipe insulation and an insulated cover. Available with either self-acting or automatic control of the domestic hot water temperature.
Application
Akva Therm 35 can be used directly in district heating systems. The domestic hot water unit has sufficient capacity to supply larger apartment complexes with 78 to 110 apartments or large buildings/commercial properties.
Description
The domestic hot water unit includes an insulated, brazed plate heat exchanger for domestic hot water production, a thermostat/controller or Danfoss ECL 110 automatic controller for domestic hot water regulation, shut-off valves, a thermometer, a balancing valve, an energy-efficient pump, a strainer, a balancing valve on the circulation line, and a safety valve and check valve on the cold water inlet. Alternatively, it can be supplied with a Danfoss ECL 310 automatic controller. Akva Therm 35 is also available as a plate heat exchanger solution with Danfoss ECL 310 automatic control.
Domestic Hot Water Heat Exchanger
The unit is based on a high-efficiency plate heat exchanger with optimal cooling of the district heating water. Akva Therm 35 is equipped with a copper-brazed heat exchanger. The domestic hot water temperature is controlled either by a thermostat or by a Danfoss ECL 110 controller, alternatively ECL 310.
Domestic Hot Water Circulation
The domestic hot water unit is supplied as standard with connections for domestic hot water circulation and is equipped with an energy-efficient pump, check valve, and balancing valve. The pump, balancing valve, and check valve are pre-mounted on the circulation line with the flow direction towards the water heater. The domestic hot water unit must always be connected to a domestic hot water circulation system. If no circulation system is available in the building installation, an internal circulation loop must be established in the plant room to ensure continuous flow on the secondary side of the water heater. Domestic hot water systems with circulation provide hot water at the tapping point without waiting time and without water wastage. This ensures optimum comfort and good district heating economy.
Service- and Installation-Friendly
A practical pipe arrangement and compact assembly of the components make the domestic hot water unit easy to service and install. Installation is quick and simple. The water heater is wall-mounted, and all connection points are positioned at a distance from the wall, making it possible to achieve neat pipework.
Akva Vita II
The Akva Vita II is an instantaneous waterheater featuring high performance andsimple operation. It is especially suitable forsingle-family houses and for systems with asimilar domestic hot water requirement.The Akva Vita II can be used directly on dis-trict heating networks with a differentialpressure of max. 2.5 bar.

EvoFlat 4.0W
Danfoss EvoFlat 4.0 station is particularly suitable for multi family buildings with central heat generation or district heating. The innovative unit sets new standard. It consists of functional blocks made of a specially reinforced PPS composite material. This makes the station extremely lightweight and limits internal heat emission. The smooth surface reduces the risks of scaling and clogging.
All components are assembled with newly designed click-fit connections. Compared to conventional substations with pipes and screw connections, this new connection technology does not require retightening during installation and commissioning.
Primary side (DH)
The flat station is equipped with two differential pressure controller and a central strainer. A summer bypass keeps the supply line warm during standstill. This ensures a fast response time for DHW during the summer. The bypass is thermostatically controlled.
Domestic hot water (DHW)
Four sizes of heat exchanger are available to cover all requirements from 37 kW up to 70 kW. The Evoflat 4.0 M is equipped with an intelligent controller that regulates the supply side flow based on the domestic hot water temperature and the volume of water drawn. The station features an integrated differential pressure controller on the supply side of the domestic hot water heating system. This eliminates the need for hydraulic balancing of the station. If necessary, the station can be expanded with a hot water circulation set.
Termix BV E
Application
The Termix BV substation is an instantaneous water heater featuring superb heat extraction and high performance. The substation is delivered with thermostatic or automatic controls. The Termix BV is suitable for large apartment houses, sports arenas and schools, where large amounts of hot water are needed. The hot water systems are available in 7 different sizes with an output from 77-222 kW. The Termix BV unit is supplied with PU insulated heat exchangers.
Domestic hot water (DHW)
The domestic hot water is prepared in a plate heat exchanger and the temperature is regulated with thermostatic or automatic controls. The thermostatic solution is regulated with self-acting thermostatic control valves. The substations with high output are controlled with two valves connected in cascade in order to control both small and large demands for hot water in an efficient manner. The Termix BV can also be mounted with automatic controls. There is no additional pressure loss on the secondary side of the heat exchanger with a thermostatic or automatic control valve. Therefore this type of regulation can be used by low pressure in the cold water mains.
District heating (DH)
The district heating circuit is prefabricated with a flow controller with integrated control valve as well as thermometers and ball valves.
Heating (HE)
The heating circuit consists of a plate heat exchanger, safety valve, manometer, thermometers, ball valves, drain valve, air valve and circulation pump. The heating circuit is controlled with an electronic controller with an outdoor temperature sensor.
Options
Termix VVX Compact 28 can be delivered with white-lacquered steel cover and filling line between primary and secondary side.
Termix Novi
Applications
The Termix Novi is an instantaneous water heater featuring superb heat extraction and high performance. The Termix Novi is suitable for flats, single-family houses as well as for small apartment buildings. The water heater is available in two sizes, either for 1 apartment, or up to 4 apartments. The Termix Novi is applicable for decentralized heating systems – as well as for district heating networks with summer operation at low temperatures or with changes in differential pressure. The heat exchanger in Termix Novi cools the district heating water very efficiently, thereby creating a very good operation economy.
Domestic hot water (DHW)
The domestic hot water is prepared in the heat exchanger and the temperature is regulated by a flow-compensated temperature controller with a integrated differential pressure controller. The Danfoss IHPT valve ensures a stable hot water temperature by varying differential pressure without the need for readjusting the valve. This protects the heat exchanger against overheating and lime scale formation. Furthermore the IHPT valve has an integrated idle temperature controller, which keeps the house supply line warm. This shortens the waiting periods during summer when the heating system is in reduced operation, which is ideal where high comfort is requested.
Options
The water heater can be supplied with a built in non-return valve and safety valve mounted in the cold water supply. The water heater can also be supplied with a thermostatic circulation valve and a non-return and pressure equalizer (GTU).
Termix One-B
Application
The Termix One is an instantaneous water heater featuring superb heat extraction and high performance. The Termix One is suitable for flats, single-family houses as well as for small apartment buildings with up to 10 apartments. The water heater is available in three sizes, either for 1 apartment, for 1-4 apartments or for 5 up to 10 apartments. The Termix One is applicable for decentralized heating systems – as well as for district heating networks with summer operation at low temperatures or changes in differential pressure. The Termix One heat exchanger cools out the district heating water very efficiently, thereby creating a very good operation economy.
Domestic hot water(DHW)
The domestic hot water is prepared in the heat exchanger and the temperature is regulated with a thermostatic control valve. The patented sensor accelerator accelerates the closing of the Danfoss AVTB valve and protects the heat exchanger against overheating and lime scale formation. The sensor accelerator and AVTB valve also works as a bypass keeping the house supply line warm. This shortens the waiting periods during summer when the heating system is in reduced operation. The sensor accelerator helps to ensure a stable hot water temperature by varying loads, flow temperatures and differential pressure without the need for readjusting the valve. There is no additional pressure loss on the secondary side of the DHW heat exchanger with a thermostatic control. Therefore this type of regulation can be used by low pressure on the in the cold water mains.
Options
The water heater can be supplied with built in non-return valve and safety valve mounted in the cold water supply. The water heater can also be supplied with a thermostatic circulation valve and a non-return and pressure equalizer (GTU).