Danfoss logo
SonoSelect_Safe left angle perspective

Energy meters, SonoSafe 10, qp [m³/h]: 0.6, Heating, Battery 1 A-cell, No integrated communication, No interface module

014U0373

Energy meter for residential applications

Product specifications

Characteristic
Value
1 Primary battery SUM weight Kg0.019
1 Primary battery weight Kg0.019
Accuracy standardClass 2 to EN1434
Ambient classE1 / M2
Ambient humidity [% RH] [Max]95 %
Ambient temperature [°C] [max]55 °C
Ambient temperature [°C] [min]5 °C
ApplicationHeating
Approval authorityForce Certification
Approved meteorological range [°C] [Max]95 °C
Approved meteorological range [°C] [Min]5 °C
Battery lifetime [Years]16 yr
Battery qty1
Battery type or NameAA Lithium (ER14505)
Cable insulation materialPVC halogen free
Cable length between calculator and flow sensor [m]0.5 m
China RoHS complianceOut of scope
Commissioning toolSonoApp
Connection sizeG 3/4
Connection typesThread
Contain batteriesYes
DG Indicator ProfileContains Lithium Batteries
DescriptionEnergy meter for residential applications
Difference temperature limits (Accounting) [K] [Max]90.00 K
Difference temperature limits (Accounting) [K] [Min]3.00 K
Display typeLCD
Dynamic range1:100
EEE category5 small equipment (any external dimension < 50 cm)
EU RoHS complianceOut of scope
Energy unitGcal
Flow measuring principleUltrasonic
Housing colorRAL 9010 White
In scope of WEEEYes
InstallationSupply
Characteristic
Value
Integrated communicationNo integrated communication
Interface module slot 1No interface module
Kvs values [m³/h]3.46 m³/h
Log storage duration [Month]24 mo
Log storage interval [Month]1 mo
Material DescriptionSonoSafe10 DN15S,qp0.6,110,L,KZ,Gcal
Material in contact with mediumBrass sensor
MediaHeating system according to VDI 2035
Media temperature [°C] [Max]95 °C
Media temperature [°C] [Min]5 °C
Other RoHS documentationEAEU RoHS
Pressure nominal [bar]16 bar
Product TypeSonoSafe 10
Product groupEnergy meters
Product lineDistrict Energy Controls
Protection class calculatorIP65
REACH Candidate List substancesLead (CAS no. 7439-92-1)
SCIP dossier no.c284e070-c802-4ced-837c-2aa2fcd3510f
SCIP dossier product nameUltrasonic Pathfinder
Storage temperature [°C] [Max]60 °C
Storage temperature [°C] [Min]-25 °C
Supply voltage typeBattery 1 A-cell
Temperature sensor approved temperature [°C] [Max]105 °C
Temperature sensor approved temperature [°C] [Min]0 °C
Temperature sensor diameter [mm]5.2 mm
Temperature sensors cable length [m]1.5 m
Temperature sensors typePt 1000
Weight per battery18 g
qc [m³/h]0.0012 m³/h
qi [m³/h]0.006 m³/h
qp [m³/h]0.6 m³/h
qs [m³/h]1.2 m³/h
qss [m³/h]1.32 m³/h

General specifications

Characteristic
Value
Gross weight0.95 Kilogram
Net weight0.704 Kilogram
Characteristic
Value
EAN/UPC5702425249006
Proposition 65Cancer and Reproductive Harm