ECL Comfort 310, LCD dot matrix, Supply voltage [V] AC: 207 - 244
087H3040
ECL COMFORT 310/230 V
Product specifications
Characteristic | Value |
|---|---|
| Actuator output load [VA] | 15.000 VA |
| Ambient humidity [% RH] [Max] | 65 % |
| Ambient temperature [°C] [max] | 55 °C |
| Ambient temperature [°C] [min] | 0 °C |
| Application source | By ECL application key |
| Approval | CE |
| Approval standard | EMC-Directive: 2004/108/ECEmission: EN 61000-6-3:2007EN 60730Immunity: EN 61000-6-1:2007LVD directive 2006/95/EC |
| CE evaluated | Yes |
| China RoHS compliance | Out of scope |
| Communications | ECL 485 Bus (non-galvanically isolated)M-BusModbus (galvanically isolated) |
| Contains batteries | No |
| Description | ECL COMFORT 310/230 V |
| DG Indicator Profile | Not relevant for dangerous goods |
| DHW functions | Anti-bacteria programAuto-tunningReturn temperature influence |
| Digital inputs type | 12 V pull-up possible |
| Display type | LCD dot matrix |
| EEE category | 5 small equipment (any external dimension < 50 cm) |
| EU RoHS compliance | Yes with exemptions |
| EU RoHS exemption clause | 6(c) |
| General functions | Alarm functionsCirculation pump exerciseControl valve exerciseExternal override facilityFrost protectionHoliday programMaster - Slave networkMotor protectionRemote control connectionVisible temperature logging |
| Grade of enclosure | IP41 |
| Heat curve setting for heating circuit | 6 pointsSlope |
| In scope of WEEE | Yes |
| Material Description | ECL COMFORT 310/230 V |
| Number of 3-point motor control outputs | 3 |
| Number of comfort periods per day | 3 |
| Number of DHW circuits | 2 |
Characteristic | Value |
|---|---|
| Number of DHW storage tank circuits | 1 |
| Number of digital inputs | 4 |
| Number of heating circuits | 3 |
| Number of pumps | 5 |
| Number of relay outputs | 6 |
| Number of Sensor inputs | 10 pc |
| Power consumption [W] | 5.0 W |
| Product group | Electronic controllers |
| Product line | District Energy Controls |
| Product Type | ECL Comfort 310 |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1)Lead monoxide (PbO, CAS no. 1317-36-8)Diboron trioxide (B2O3, CAS no. 1303-86-2)Lead titanium trioxide (CAS no. 12060-00-3)6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol (CAS no. 119-47-1) |
| Relay output inductive load [A] | 2 A |
| Relay output ohmic load [A] | 4 A |
| Relay output voltage [V] AC | 230 V |
| SCIP dossier no. | ad51fccb-924b-4843-a9b7-7e3da2fef171 |
| SCIP dossier product name | ECL Comfort 310 and 210 |
| Sensor cable length [m] | 200.00 m |
| Storage temperature [°C] [Max] | 70 °C |
| Storage temperature [°C] [Min] | -40 °C |
| Supply voltage [V] AC | 230 V |
| Supply voltage [V] AC [max] | 244 V |
| Supply voltage [V] AC [min] | 207 V |
| Supply voltage frequency [Hz] | 50 Hz |
| Temperature sensors type | Pt 1000, configurable input |
| Time switch power backup [h] | 72 h |
| Time switch type | Week |
| User input type | DisplayPush-turn dial |
General specifications
Characteristic | Value |
|---|---|
| Gross weight | 0.682 Kilogram |
| Net weight | 0.476 Kilogram |
| Volume | 4.877 Liter |
Characteristic | Value |
|---|---|
| EAN/UPC | 5710104013244 |
| Proposition 65 | Cancer and Reproductive Harm |