ECL Comfort 110, Supply voltage [V] AC: 22 - 26, Time switch type: No time switch
087B1251
ECL Comfort 110 - 24 V a.c.
This product has been discontinued.
The product is no longer available for purchase, but you can still find information about it, including service manuals, drawing etc.
If you're looking for a similar product, you can check out other options within the same product type by visiting the product type page.: ECL comfort controllers
Recommended replacement: 087B1262
Product specifications
Characteristic | Value |
|---|---|
| Actuator output load [VA] | 15.000 VA |
| Ambient humidity [% RH] [Max] | 65 % |
| Ambient temperature [°C] [max] | 55 °C |
| Ambient temperature [°C] [min] | 0 °C |
| Application source | On-board |
| Approval | CE |
| Approval standard | EMC-Directive: 2004/108/ECEmission: EN 61000-6-3:2007Immunity: EN 61000-6-1:2007LVD directive 2006/95/EC |
| CE evaluated | Yes |
| Communications | ECL-Bus (non-galvanically isolated) |
| Contains batteries | No |
| Description | ECL Comfort 110 - 24 V a.c. |
| DG Indicator Profile | Not relevant for dangerous goods |
| DHW functions | Auto-tunningReturn temperature influence |
| Display type | LCD custom design |
| EEE category | 5 small equipment (any external dimension < 50 cm) |
| General functions | Circulation pump exerciseControl valve exerciseExternal override facilityFrost protectionMaster - Slave networkMotor protectionRemote control connection |
| Grade of enclosure | IP41 |
| Heat curve setting for heating circuit | Slope |
| In scope of WEEE | Yes |
| Material Description | ECL Comfort 110 - 24 V a.c. |
| Number of 3-point motor control outputs | 1 |
| Number of DHW circuits | 1 |
| Number of digital inputs | 1 |
| Number of heating circuits | 1 |
Characteristic | Value |
|---|---|
| Number of pumps | 1 |
| Number of relay outputs | 1 |
| Number of Sensor inputs | 4 pc |
| Power consumption [W] | 3.0 W |
| Product group | Electronic controllers |
| Product line | District Energy Controls |
| Product Type | ECL Comfort 110 |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
| Relay output inductive load [A] | 2 A |
| Relay output ohmic load [A] | 4 A |
| Relay output voltage [V] AC | 230 V |
| Sensor cable length [m] | 125.00 m |
| Sensor cable length [mm] | 125 mm |
| Storage temperature [°C] [Max] | 70 °C |
| Storage temperature [°C] [Min] | -40 °C |
| Supply voltage [V] AC | 24 V |
| Supply voltage [V] AC [max] | 26 V |
| Supply voltage [V] AC [min] | 22 V |
| Supply voltage frequency [Hz] | 50 Hz |
| Temperature sensors type | Pt 1000 |
| Time switch power backup [h] | 12 h |
| Time switch type | No time switch |
| User input type | DisplayPush buttons |
General specifications
Characteristic | Value |
|---|---|
| Gross weight | 0.539 Kilogram |
| Net weight | 0.539 Kilogram |
| Volume | 2.155 Liter |
Characteristic | Value |
|---|---|
| EAN/UPC | 5702421067741 |
| Proposition 65 | Cancer and Reproductive Harm |