Indirect heating and DHW tank
Product types shown: 3

Termix BVX FI RO
Application
The Termix BVX FI RO T/E substation is a complete solution for hot water and space heating with optimal safety, efficient energy transfer, servicefriendly construction and a compact design. The substation is used if a heat exchanger is required or on a conversion to district heating where the existing equipment is unsuitable for direct connection.
District heating (DH)
The substation is prefabricated with a differential pressure controller, fitting piece and sensor pockets for insertion of a heat meter as well as strainers and ball valves.
Heating (HE)
The heating circuit consists of a plate heat exchanger, safety valves, pressure gauge, ball valves, drain valve, air valves, expansion vessel and circulation pump. The temperature of the heating is controlled by an electronic controller with an outdoor temperature sensor.
Domestic hot water (DHW)
The domestic hot water circuit consists of a hot water tank with coil and selfacting thermostatic control valve. The DHW tank and coil are enamelled and the tank contains a magnesium anode.
Options
The Termix BVX FI RO T/E can be supplied with a thermostatic circulation valve or a built-in non-return valve. Option delivered loose with the unit.
Termix BVX FI RO SEK
Application
The Termix BVX-FI RO SEK substation is a complete solution for hot water and space heating with optimal safety, efficient energy transfer, service-friendly construction and a compact design. The substation is used if a heat exchanger is required or on a conversion to district heating where the existing equipment is unsuitable for direct connection.
District heating (DH)
The substation is prefabricated with a differential pressure controller, fitting piece and sensor pockets for insertion of a heat meter as well as strainers and ball valves.
Heating (HE)
The heating circuit consists of a plate heat exchanger, safety valves, pressure gauge, ball valves, drain valve, air valves, expansion vessel and circulation pump. The temperature of the heating is electronically controlled with an outdoor temperature sensor.
Domestic hot water (DHW)
The domestic hot water circuit consists of a hot water tank with coil and a pump for controlling the temperature with possibility for DHW priority. The DHW tank and coil are enamelled and the tank contains a magnesium anode.
Options